Emulex 110 Guide d'installation Page 60

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 240
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 59
60
EMC Host Connecivity with Emulex Fibre Channel HBAs and CNAs in the Windows Environment
Installation and Configuration
27. Select 1 (Scan Targets) to instruct the adapter to scan for attached
targets, and press Enter.
This displays a window similar to Figure 39.
Figure 39 Targets
28. Select the number that corresponds to the array target port from
which the boot will be configured, and press Enter.
This displays a window similar to Figure 40 on page 61.
In Figure 39, the array designated by 002: DID:2C1900
WWN:5006048A CD201641 is the array from which the boot will
be configured.
Note: If no target numbers appear, and the utility simply returns to the
prior screen, verify the following:
If multiple adapters are present, verify that the adapter selected in the
BIOS utility is the one that currently provides the I/O path to the
storage. (At this point, only one I/O path should be configured to the
boot LUN.)
For VNX series or CLARiiON systems, verify that the single I/O path
points to the SP that owns the boot LUN.
For FC-SW environments, verify fabric zoning parameters, such that
a single I/O path exists to the boot LUN. Refer to your array software
documentation for details.
Check the physical Fibre Channel connectivity between the adapter
and array (direct-attach environment) or switch (FC-SW
environment).
Vue de la page 59
1 2 ... 55 56 57 58 59 60 61 62 63 64 65 ... 239 240

Commentaires sur ces manuels

Pas de commentaire