EMC Host Connecivity with Emulex Fibre Channel HBAs and CNAs in the Windows Environment
Installation and Configuration
Figure 19 Setting the primary boot LUN
A list representing all array targets visible to the adapter is
presented. In this example, a single array is zoned to the adapter.
15. Select the two-digit row number corresponding to the array to be
used for boot (01 in this example) and press Enter.
This displays a screen similar to Figure 20 on page 45.
Note: If no entries (other than 00) appear, verify the following:
If multiple adapters are present, verify the adapter selected in the
BIOS utility is the same adapter that currently provides the I/O path
to the storage. (At this point, only one I/O path should be configured
to the boot LUN.)
For VNX
series or CLARiiON
®
systems, verify the single I/O path
points to the SP that owns the boot LUN.
For FC-SW environments, verify fabric-zoning parameters, such that
a single I/O path exists to the boot LUN. (Refer to your array
software documentation for details.)
Check the physical Fibre Channel connectivity between the adapter
and array (direct-attach environment) or switch (FC-SW
environment).